The cast steel wall module connects a support arm in the X-M system to a vertical mounting surface and forms the wall-side connection point of the assembly. It is intended for a horizontal support-arm connection. The joint allows the arm to pivot through 90° to the left and right so that the connected operating unit can be aligned at the workstation. Bellows enclose the moving joint area.
Weight
3330 g
Material
Steel Casting
Colour
RAL 7035 / Bellow RAL 7016
Package Dimensions
185 × 155 × 135 mm
HS Code
7606.99.90.19
Warranty
5 years

Technical data

Specifications for planning, selection and use at a glance.

Material & finish

Material Composition
Steel Casting
Colour
RAL 7035 / Bellow RAL 7016
RAL colours
RAL 7035 / RAL 7016

Application & function

Operating Weight
3330 g
Primary Use Case
Machine Building / Automation / HMI operator stations
Operating Temperature
–40°C to +70°C
Protection Rating
–IP65 (DIN EN 60529)
Rated Voltage
Mechanical (not subject to electrical certification)
Movement
Right 90° - Left 90°

Safety & compliance

Earthing
Yes, integrated solution
RoHS Compliance
RoHS EU Directive 2011/65/EU
REACH Compliance
REACH Regulation 1907/2006/EC
Certification
IEC 60529; (EG) No. 765/2008; (EU) 2023/956

Further information

Movement type
schwenkbar
Swivel angle right
90 deg
Swivel angle left
90 deg

Version & enquiry

Use the item number and version to prepare your enquiry.

  • SKU: X-M-WMF01

    Weight (g)
    3330

Product documents

Product files and documentation together in one place.

Data sheets with the new article numbers are not yet available. Please request the documents you need.

Files: 7 of 7

Search filenames
ZIP 1 file
PDF 6 files
  • X-M-WMF01-Assembly-de-DE.pdf

    2.2 MB

  • X-M-WMF01-Connection-dimensions-de-DE.pdf

    6.9 kB

  • X-M-WMF01-Assembly-en-GB.pdf

    2.2 MB

  • X-M-WMF01-Connection-dimensions-en-GB.pdf

    6.9 kB

  • X-M-WMF01-Connection-card-de-DE.pdf

    1.1 MB

  • X-M-WMF01-Connection-card-en-GB.pdf

    1.1 MB

Assembly instructions

About these instructions

Assembly sequence prepared from the exact XINDUX article data sheet. Tightening torques not specified in the source document are deliberately not added.

Preparation & tools

Supplied and installation parts

Supplied and installation parts

Required tools

  • Allen key suitable for the fasteners
  • Torque wrench for the final engineering check

Step 1 / 13 · Prepare the components

  1. Prepare the components

    1. Prepare the components

    The supporting axis of the module must be aligned vertically in accordance with the example assembly shown. Other mounting orientations are not permitted.

  2. Fasten the connection

    2. Fasten the connection

    Insert the angle bolts into their slots and tighten.

    • M6 × 20
  3. Insert the gasket

    3. Insert the gasket

    Remove the yellow tape. Place the gasket with the adhesive surface facing inwards.

  4. Connect the profile

    4. Connect the profile

    Insert the profile into the coupling as shown in the figure on the left.

    • M6 × 20
  5. Fasten the connection

    5. Fasten the connection

    Tighten the profile bolts.

    • M6 × 30
    • J6.4
    • M6
  6. Align the system

    6. Align the system

    Angle bolts are used to prevent the profile from sagging due to the heavy weight that can occur with long support arm profiles. Use M6×20 screws for angle correction. If sagging does not occur in your application, leave the angle bolts in the tightened position. If there is deflection in your application, loosen the M6 ​​× 30 profile bolts by 2-3mm depending on the desired angle. Once the profile is adjusted to the desired position, retighten the M6 ​​× 30 angle screws. Then check the inclination with a spirit level.

    • M6 × 20
    • M6 × 30
  7. Fit the cover

    7. Fit the cover

    Install the bellows in the direction of the arrow as shown in the figure to cover the module.

  8. Fit the cover

    8. Fit the cover

    Insert the bellows coupling parts into the slots on the two ends of the bellows and tighten them well.

  9. Fit the cover

    9. Fit the cover

    Check the bellows for a good fit.

  10. Insert the gasket

    10. Insert the gasket

    Remove the yellow tape. Insert the gasket so that the adhesive surface faces inward.

  11. Mount module on the wall

    11. Mount module on the wall

    M8 wall mounting bolts are not included in the packaging.

    M8 wall mounting bolts are not included in the packaging.

    • M8
  12. Fit the cover

    12. Fit the cover

    Don't forget to install the module's plastic covers.

    Don't forget to install the module's plastic covers.

  13. Prepare the mounting holes

    13. Prepare the mounting holes

    Prepare four mounting holes Ø 8.6 mm with horizontal centre spacing 92 mm and vertical centre spacing 78 mm according to the drawing. All dimensions in millimetres.