PANEL COUPLING
Rotatable Panel Adaptor Vertical
- Weight
- 930 g
- Material
- Aluminum
- Colour
- RAL 7035
- Package Dimensions
- 140 × 120 × 110 mm
- HS Code
- 7606.99.90.19
- Warranty
- 5 years
Technical data
Specifications for planning, selection and use at a glance.
Material & finish
- Material Composition
- Aluminum
- Colour
- RAL 7035
- RAL colours
- RAL 7035
Application & function
- Operating Weight
- 930 g
- Primary Use Case
- Machine Building / Automation / HMI operator stations
- Operating Temperature
- –40°C to +70°C
- Protection Rating
- –IP65 (DIN EN 60529)
- Rated Voltage
- Mechanical (not subject to electrical certification)
- Movement
- Rotatable 350°
- Rotation angle
- 315 deg
Safety & compliance
- Earthing
- Yes, integrated solution
- RoHS Compliance
- RoHS EU Directive 2011/65/EU
- REACH Compliance
- REACH Regulation 1907/2006/EC
- Certification
- IEC 60529; (EG) No. 765/2008; (EU) 2023/956
Further information
- Adapter surface
- 118 × 65 mm
Version & enquiry
Use the item number and version to prepare your enquiry.
| Choose a version | ||
|---|---|---|
| SKU: X-M-PAD01 | 930 |
SKU: X-M-PAD01
- Weight (g)
- 930
Assembly instructions
About these instructions
Assembly sequence prepared from the exact XINDUX article data sheet. Tightening torques not specified in the source document are deliberately not added.
Preparation & tools
Supplied and installation parts

Required tools
- Allen key suitable for the fasteners
- Torque wrench for the final engineering check

1. Align the system
Insert the switching lever into the slot. The switching lever is used to adjust the torsional rigidity of the module.
- M5 × 16

2. Insert the gasket
Remove the yellow tape. Insert the gasket so that the adhesive surface faces inward.

3. Connect the profile
Insert the profile into the coupling as shown in the figure on the left.

4. Fasten the connection
Tighten the profile bolts.
- M6 × 30
- J6.4

5. Insert the gasket
Remove the yellow protective tape. Insert the panel-side seal with the adhesive surface to the adapter housing into the seal holder on the underside without folding.

6. Fasten the module to the panel
Place the module on the plate.

7. Inspect the assembly
Make sure the assembly has been carried out correctly as shown in the figure.

8. Fasten the module to the panel
The mounting screws are not included.
Attach the module to the panel with four M6 × 30 screws. The mounting screws are not included.
- M6 × 30

9. Fasten the module to the panel
Check the module and panel connections for proper assembly.

10. Prepare the mounting holes
If required, prepare the mounting holes according to the dimensioned drawing. All dimensions are given in millimetres.
Select a step or use the arrows. On mobile, swipe left or right.
Products in this series
Panel Tilting Adaptor
Ø48 Adaptor
Rotatable Panel Coupling
Rotatable Panel Coupling
080/Ø48 Adaptor
Ø134 mm 10° Panel Adaptor
Wall-Socket Mounting Bracket
080 / 050 Support Arm Adaptor
Warning Lamp Cover (M22)
Vesa Panel Tilting Adaptor Moving
Panel Coupling
080 Panel Adaptor
10° Angle Piece
Ø134 mm Panel Adaptor
Ø130 mm Panel Tilting Adaptor - With Bellows
Warning Lamp Cover (M18)
Height Adjustable Support Arm
Rotatable Wall-Mounted Hinge Vertical Outlet
Rotatable Top Mounted 90° Angle Joint
90° Angle Piece
Steel Wall Mounted Module - With Bellows
Steel Interconnection Module - With Bellows
Rotatable Wall-Mounted Hinge Horizontal Outlet
Rotatable Top Mounted Vertical Outlet
Rotatable Panel 90° Angle Coupling
Rotatable profile joint
Ø48 Pipe Profile
Rotatable Intermediate Hinge
Mobile HMI PC cabinet station
HMI base
mobile kiosk base with castors
080 Support Profile - 1000mm · X-M