The fixed angle adapter provides a connection with a 10° inclination for the operator enclosure in the X-M support-arm system. The angle is defined by the design and is not adjusted through a joint. Positioned between the coupling and enclosure, the adapter sets the inclination of the operating unit. It is used where a fixed enclosure orientation is required, with additional movement provided by other system joints.
Weight
190 g
Material
Aluminum
Colour
RAL 7035
Package Dimensions
170 × 35 × 80 mm
HS Code
7606.99.90.19
Warranty
5 years

Technical data

Specifications for planning, selection and use at a glance.

Material & finish

Material Composition
Aluminum
Colour
RAL 7035
RAL colours
RAL 7035

Application & function

Operating Weight
190 g
Primary Use Case
Machine Building / Automation / HMI operator stations
Operating Temperature
–40°C to +70°C
Protection Rating
–IP65 (DIN EN 60529)
Rated Voltage
Mechanical (not subject to electrical certification)
Movement
Fixed

Safety & compliance

Earthing
Yes, integrated solution
RoHS Compliance
RoHS EU Directive 2011/65/EU
REACH Compliance
REACH Regulation 1907/2006/EC
Certification
IEC 60529; (EG) No. 765/2008; (EU) 2023/956

Further information

Movement type
fest
Angle
10 deg

Version & enquiry

Use the item number and version to prepare your enquiry.

  • SKU: X-M-WA01

    Weight (g)
    190

Product documents

Product files and documentation together in one place.

3 files

ZIP 1 file
PDF 2 files
  • X-M-WA01-Produktunterlagen-DE.pdf

    667.3 kB

  • X-M-WA01-Produktunterlagen-EN.pdf

    663.7 kB

Assembly instructions

About these instructions

Assembly sequence prepared from the exact XINDUX article data sheet. Tightening torques not specified in the source document are deliberately not added.

Preparation & tools

Supplied and installation parts

Supplied and installation parts

Required tools

  • Allen key suitable for the fasteners
  • Torque wrench for the final engineering check

Step 1 / 6 · Insert the gasket

  1. Insert the gasket

    1. Insert the gasket

    Remove the yellow tape. Insert the gasket so that the adhesive surface faces inward.

  2. Insert the gasket

    2. Insert the gasket

    Check whether the seal is seated well.

  3. Prepare the components

    3. Prepare the components

    Combine the modules step by step as shown in the figure.

    • M6 × 30
    • J6.4
  4. Fasten the module to the panel

    4. Fasten the module to the panel

    Bolts and washers are not included.

    Place the module on the panel. Bolts and washers are not included.

  5. Fasten the connection

    5. Fasten the connection

    Tighten the profile bolts.

  6. Prepare the mounting holes

    6. Prepare the mounting holes

    If required, prepare the mounting holes according to the dimensioned drawing. All dimensions are given in millimetres.