PANEL COUPLING
Panel Coupling
- Weight
- 480 g
- Material
- Aluminum
- Colour
- RAL 7035
- Package Dimensions
- 135 × 40 × 135 mm
- HS Code
- 7606.99.90.19
- Warranty
- 5 years
Technical data
Specifications for planning, selection and use at a glance.
Material & finish
- Material Composition
- Aluminum
- Colour
- RAL 7035
- RAL colours
- RAL 7035
Application & function
- Operating Weight
- 480 g
- Primary Use Case
- Machine Building / Automation / HMI operator stations
- Operating Temperature
- –40°C to +70°C
- Protection Rating
- –IP65 (DIN EN 60529)
- Rated Voltage
- Mechanical (not subject to electrical certification)
- Movement
- Fixed
Safety & compliance
- Earthing
- Yes, integrated solution
- RoHS Compliance
- RoHS EU Directive 2011/65/EU
- REACH Compliance
- REACH Regulation 1907/2006/EC
- Certification
- IEC 60529; (EG) No. 765/2008; (EU) 2023/956
Further information
- Diameter
- 134 mm
- Movement type
- fest
Version & enquiry
Use the item number and version to prepare your enquiry.
| Choose a version | ||
|---|---|---|
| SKU: X-L-PKF01 | 480 |
SKU: X-L-PKF01
- Weight (g)
- 480
Assembly instructions
About these instructions
Assembly sequence prepared from the exact XINDUX article data sheet. Tightening torques not specified in the source document are deliberately not added.
Preparation & tools
Supplied and installation parts

Required tools
- Allen key suitable for the fasteners
- Torque wrench for the final engineering check

1. Insert the gasket
Remove the yellow tape. Insert the gasket so that the adhesive surface faces inward.

2. Connect the profile
Insert the profile into the coupling as shown in the figure on the left.

3. Fasten the connection
Install the M8 × 40 profile bolts.
- M8 × 40
- J8.4

4. Fasten the module to the panel
The mounting screws are not included. Source conflict: the assembly instructions specify M8 × 30 for panel mounting; the interface drawing shows Ø7 mm holes. Confirm the correct bolt and hole assignment with the manufacturer before installation.
Attach the module to the panel with four M8 × 30 screws. The mounting screws are not included. Check that the assembly was carried out as shown in the illustration and that the panel is seated correctly.
- M8 × 30

5. Prepare the mounting holes
If required, prepare the mounting holes according to the dimensioned drawing. All dimensions are given in millimetres.
Select a step or use the arrows. On mobile, swipe left or right.
Products in this series
Warning Lamp Cover (M22)
Rotatable Panel Coupling
Warning Lamp Cover (M18)
130/080 Support Arm Adaptor
Wall-Socket Mounting Bracket
Height Adjustable Support Arm
Steel Wall Mounted Module - With Bellows
Rotatable Intermediate Hinge
Rotatable Wall-Mounted Hinge Horizontal Outlet
Rotatable Top Mounted Vertical Outlet
90° Angle Piece
Rotatable Panel 90° Angle Coupling
Rotatable Top Mounted 90° Angle Joint
Rotatable profile joint
Steel Interconnection Module - With Bellows
Rotatable Wall-Mounted Hinge Vertical Outlet
kiosk base with levelling feet
kiosk base with flange
mobile kiosk base with castors
130 Support Profile - 1000mm · X-L