The rotary angle panel coupling connects a support arm in the X-S system to the operator enclosure through a 90° change of direction. Its angled form turns the connection around a corner, while the rotary connection allows the panel to be aligned. Positioned directly at the enclosure connection, it combines a change of direction with movement, allowing the operating unit to be aligned with the workstation within this connection arrangement.
Weight
1000 g
Material
Aluminum
Colour
RAL 7035 / Cover RAL 7016
Package Dimensions
140 × 155 × 110 mm
HS Code
7606.99.90.19
Warranty
5 years

Technical data

Specifications for planning, selection and use at a glance.

Material & finish

Material Composition
Aluminum
Colour
RAL 7035 / Cover RAL 7016
RAL colours
RAL 7035 / RAL 7016

Application & function

Operating Weight
1000 g
Primary Use Case
Machine Building / Automation / HMI operator stations
Operating Temperature
–40°C to +70°C
Protection Rating
–IP65 (DIN EN 60529)
Rated Voltage
Mechanical (not subject to electrical certification)
Movement
Rotatable 315°
Rotation angle
315 deg

Safety & compliance

Earthing
Yes, integrated solution
RoHS Compliance
RoHS EU Directive 2011/65/EU
REACH Compliance
REACH Regulation 1907/2006/EC
Certification
IEC 60529; (EG) No. 765/2008; (EU) 2023/956

Version & enquiry

Use the item number and version to prepare your enquiry.

  • SKU: X-S-PWK01

    Weight (g)
    1000

Product documents

Product files and documentation together in one place.

3 files

ZIP 1 file
PDF 2 files
  • X-S-PWK01-Produktunterlagen-DE.pdf

    1.6 MB

  • X-S-PWK01-Produktunterlagen-EN.pdf

    1.6 MB

Assembly instructions

About these instructions

Assembly sequence prepared from the exact XINDUX article data sheet. Tightening torques not specified in the source document are deliberately not added.

Preparation & tools

Supplied and installation parts

Supplied and installation parts

Required tools

  • Allen key suitable for the fasteners
  • Torque wrench for the final engineering check

Step 1 / 12 · Align the system

  1. Align the system

    1. Align the system

    Insert the switching lever into the slot. The switching lever is used to adjust the torsional rigidity of the module.

    • M5 × 16
  2. Insert the gasket

    2. Insert the gasket

    Remove the yellow tape. Insert the profile-side connection seal with the adhesive surface to the component into the seal holder shown without folds.

  3. Connect the profile

    3. Connect the profile

    Insert the profile into the coupling as shown in the figure on the left.

  4. Fasten the connection

    4. Fasten the connection

    Tighten the profile bolts.

    • M6 × 30
    • J6.4
  5. Insert the gasket

    5. Insert the gasket

    Remove the tape. Insert the gasket so that the adhesive surface faces inward.

  6. Fit the cover

    6. Fit the cover

    Place the cover on the module and tighten the screws.

    • M4 × 8
  7. Set the rotation range

    7. Set the rotation range

    Attention: The angle limiting screw (M6 × 10) can be used when the module rotation angle is to be reduced.

    Attention: The angle limiting screw (M6 × 10) can be used when the module rotation angle is to be reduced. There are 6 holes on the module.

    • M6 × 10
  8. Insert the gasket

    8. Insert the gasket

    Remove the yellow tape. Insert the seal to the mounting surface with the adhesive surface to the component into the seal holder shown without folds.

  9. Fasten the module to the panel

    9. Fasten the module to the panel

    Before installing the panel, check whether the pre-assembled module is closed and all components are fully seated.

  10. Fasten the module to the panel

    10. Fasten the module to the panel

    The screws are not included.

    Place the module above the panel. The screws are not included.

    • M6 × 30
  11. Fasten the module to the panel

    11. Fasten the module to the panel

    After installing the panel, check whether the module and panel are in full contact, firmly and without any visible gaps.

  12. Prepare the mounting holes

    12. Prepare the mounting holes

    If required, prepare the mounting holes according to the dimensioned drawing. All dimensions are given in millimetres.

Select a step or use the arrows. On mobile, swipe left or right.