Ex Aluminum Enclosures

GBAEX enclosures are based on the proven GBA aluminium platform and configured for explosion-protected projects with external earthing and nameplate marking. The range supports Ex e (increased safety) and Ex i (intrinsic safety) concepts with project-specific certification scope.

The matrix includes 34 sizes from 58 x 64 x 34 mm up to 600 x 310 x 180 mm, with PDF drawings and 3D STEP models available for engineering.

Weight

150 to 12000 g

Material

Aluminium AlSi12

Color

RAL7001, special colours on request

Size Range

58 x 64 x 34 to 600 x 310 x 180 mm

HS Code

85369030

Special Options

Ex e / Ex i, U/K versions

Additional Information

Material Composition

Aluminium platform based on GBA

Protection

Ex-oriented construction for hazardous area projects

Surface

Powder Coated (structured, silky & shiny)

Primary Use Case

Explosion-protected machine and process areas

Operating Temperature

According to final approved project components

Protection Rating

IP66 (DIN EN 60529)

Earthing

Yes, external earthing connection on lower part

RoHS Compliance

RoHS EU Directive 2011/65/EU

REACH Compliance

REACH Regulation 1907/2006/EC

Compatibility

Mechanical platform continuity with GBA size family (project release dependent)

XINDUX ItemsLength (mm)Width (mm)Height (mm)Weight (g)Mounting PlateHinges3D Models
GBAEX000586434586434150 -
GBAEX000758057758057350 -
GBAEX000986434986434200 -
GBAEX01001008110010081650 -
GBAEX012212081122120811000 -
GBAEX012212090122120901050 -
GBAEX0012580571258057450 -
GBAEX014014091140140911350 -
GBAEX0015064341506434300 -
GBAEX01601008116010081850 -
GBAEX016016091160160911600 -
GBAEX0017580571758057600 -
GBAEX1801801001801801002100 -
GBAEX020014090200140901650 -
GBAEX2002301132002301132800 -
GBAEX2002301802002301804050 -
GBAEX022012081220120811500 -
GBAEX022012091220120911650 -
GBAEX0025080572508057850 -
GBAEX026016091260160912300 -
GBAEX2801801002801801002800 -
GBAEX2802301102802301103350 -
GBAEX3302301113302301113800 -
GBAEX3302301803302301803600 -
GBAEX036012080360120802050 -
GBAEX036016090360160903000 -
GBAEX4002301104002301105400 -
GBAEX4002301804002301806150 -
GBAEX4003101104003101107100 -
GBAEX4003101804003101808850 -
GBAEX056016090560160904000 -
GBAEX6002301106002301107250 -
GBAEX6003101106003101109250 -
GBAEX60031018060031018012000 -

FAQs

U is the Ex-certified empty housing. K is the populated Ex terminal housing with project-specific internal equipment.

34 sizes, from 58 × 64 × 34 mm up to 600 × 310 × 180 mm.

IP66 is standard for GBAEX housings.

U = Ex-certified empty housing; K = populated Ex terminal housing with project-specific internal equipment.

The range supports Ex e (increased safety) and Ex i (intrinsic safety) depending on project requirements.

Yes, GBAEX includes an external earthing connection on the lower part as part of the Ex-oriented design.

Yes, nameplate included as part of the Ex execution.

A broad Ex matrix exists, but final release depends on certification scope and selected configuration.

All attached and internal components must comply with the applicable Ex approvals for the final assembly.

Yes, K versions can be configured with terminal systems, entries, and internal arrangement according to approved project design.

Yes, matrix models are provided with PDF and STEP data for faster layout/documentation work.

150 to 12,000 g depending on model.

Model dependent, matrix indicates mounting plate and hinge availability per item.

Documentation scope and configuration follow the project approval path; XINDUX aligns the enclosure setup to the required Ex concept and certification package.

Yes, entries and internal arrangement can be defined project-wise (especially for K versions).

Zone/concept (Ex e or Ex i), U vs K, required entries/terminals, approval scope, earthing/identification needs, and any internal component constraints (approved parts only).

Yes, availability is listed as in stock (standard matrix).

Any component or entry changes must be evaluated against the Ex approvals and the approved project design before release.

The datasheet states nameplate included; additional marking/identification is typically handled within the project-specific Ex documentation/configuration scope.

Freeze the approval scope early, supply the entry layout + terminal list up front, and keep all internal components aligned with project approvals.

Frequently Asked Questions

Our High-Voltage Circuit Breaker is certified to IEC 62271 and IEEE C37 standards, ensuring compliance with international safety and performance requirements. Additional regional certifications include CE, UL, and CCC marks for global market acceptance.

Yes, we offer comprehensive OEM customization services including voltage ratings, mounting configurations, control interfaces, and branding options. Our engineering team works closely with clients to develop tailored solutions that meet specific application requirements.

Standard configurations are typically available within 4–6 weeks. Custom orders require 8–12 weeks depending on specification complexity. We maintain strategic inventory for common models to support urgent project requirements.

XINDUX provides comprehensive global technical support through our network of regional service centers. This includes installation guidance, commissioning assistance, preventive maintenance programs, and 24/7 emergency response capabilities across all major markets.

You may also like